WORLD-CLASS FACILITIES

Photo

MULTIPLE
SERVICE PROVIDERS

Photo

QUALITY POWER
PRICED AT LOW RATE

Photo

FACADE
– ENERGY EFFICIENT
DOUBLE GLAZED UNITS

100%
POWER BACKUP

Photo

MULTIPLE
SERVICE PROVIDERS

Photo

QUALITY POWER
PRICED AT LAW RATE

AMENITIES

Photo

FOOD COURT

BANKs

ATMs

LANDSCAPED GARDENS

100% POWER BACKUP

1500+ CAR PARKINGS

FACADE – ENERGY EFFICIENT DOUBLE GLAZED UNITS

BUILDING SPECIFIC DETAILS

Frontage of the plot 132.82 Meter plot frontage
Road Width 40.60 Meter
Height of the Building 75m
No. of accesses to each Block Vehicular entry – 2 nos., vehicular exit – 2 nos.
No. of Floors G+19
Total Built-up Area 14,63,603 Sq.ft
Floor Plate Size (Sq.ft) 83,896 Sq.ft
No. of Basements NIL
Usage of Basement NA
External Finish Energy efficient double glazed units
Design Load: (Floor finish + partition load + services+equipment+live load) Office space – 770 KG / Sq.m, Server room area – 1770 Kg / Sq.m
Type of construction Framed structure
Column grid measurement (Centre to Centre) 12m
No. of Lifts 18 Nos.
Passenger Lifts 16 Nos.
Service Lifts 2 Nos.

TECHNICAL DETAILS

3a. POWER Kinesco power and utilities pvt. ltd. – Licensee
Power (KINESCO) 11 kV INCOMERS – 2 NOS. + 1 NO. SPARE
Total Capacity Installed 6600 kVA
No. of Transformers Installed Main Building: (3 Nos. of 1600 kVA + 1 No. of 630 kVA), Utility Building: 2 Nos. of 2000 kVA
Power allotted per 100 sq.ft. 0.5 kVA per 100 SQ.FT EXCLUDING HVAC
Total back-up Power Planned 8250 kVA
Back-up Power for each floor 100%
Back-up Power for AC 100%
DG Set Capacity 1250 kVA – 3 NOS. (FOR CHILLERS), 1500 kVA – 3 NOS. (FOR OFFICE SPACE)
Make of the DG Set STERLING & WILSON
Place where the DG set is kept UTILITY BLOCK
DG set type RADIATOR COOLED TYPE, FUEL – HSD
UPS PROVIDED FOR COMMON AREA LIGHTING
3b. AC AVAILABILITY
Type of AC CENTRALISED AC WITH CHILLER PLANT
AC Capacity (TOTAL – 3150 TR) WATER COOLED – 3 NOS. X 800 TR, AIR COOLED – 3 NOS.X 250 TR
AHUs TENANT’S SCOPE
Place wherein the AC unit are installed UTILITY BLOCK
Provision of Tenant Metering of AC consumption BTU METER
3c. FIRE STANDARDS
No. of Fire Exits FOUR (4) NOS. IN EACH FLOOR
Fire Hydrants PROVIDED
Fire Alarms PROVIDED ABOVE FALSE CEILING
Smoke Detectors PROVIDED ABOVE FALSE CEILING
Sprinklers PROVIDED ABOVE FALSE CEILING
3d. UNIT
Ceiling Height Slab to Slab 4.05 METER
Clear Height (Slab Thickness: 275mm, Screed Thickness: 65mm) 3.71 METER
3e. TOILETS (Per Floor)
Male – 3 NOS. TOILETS 15 NOS. WCs , 16 NOS. URINALS & 14 NOS. WASHBASINS
Female – 3 NOS. TOILETS 24 NOS. WCs & 17 NOS. WASHBASINS
Physically Challenged Toilets 3 NOS. PER FLOOR
Toilet Floor Finish VITRIFIED TILE
3f. FLOORING
In the Lobby IMPORTED MARBLE
Staircase GRANITE
Inside the shell SCREED FINISH IN OFFICE AREA
3g.PARKING
Multi Level Car Parking(MLCP) MLCP has 1300 covered car parking slots with 3 ramps each of 6 meter wide in addition to 1 VIP ramp
Car Park Ratio ONE (1) NO. CAR PARK FOR EVERY 800 SQ.FT SUPER BUILT-UP AREA LEASED
3h.WATER
Is water treatment plant available?. Yes
Is Sewerage Treatment Plant Available?. Yes
PRINCIPAL ARCHITECT THOMAS ASSOCIATES, BENGALURU